Handed ultrasonic flow meter for water
Installation
Ultrasonic flowmeter generally have two probe installation, Z method and V method.
However, when D <200mm and the scene is one of the following conditions can also be installed using the Z method:
1, when the measured fluid turbidity is high, measured by V method can not receive the signal or signal is weak;
2, when the lining of the pipeline wall;
3, when the pipeline life is too long and the wall scale serious;
For pipe conditions are better, even if D is slightly larger than 200mm, in order to improve the measurement accuracy, can also be installed by V method.